Instructions for Conversion of Commercial Electric Models 
 
 
8
 
Phase Conversion Only kits 
 
Table 2. Phase Conversion Kits. 
6KW 
9KW 
12KW 
Volts 
Conversion 
Kit 
Volts
Conversion 
Kit 
Volts
Conversion 
Kit 
208 265-45246-13 208 265-45246-14 208 265-45246-15 
240 265-45246-07 240 265-45246-08 240 265-45246-09 
480 265-45246-01 480 265-45246-02 480 265-45246-03 
13.5KW 
15KW 
18KW 
Volts 
Conversion 
Kit 
Volts
Conversion 
Kit 
Volts
Conversion 
Kit 
208 265-45246-16 208 265-45246-17 208 265-45246-18 
240 265-45246-10 240 265-45246-11 240 265-45246-12 
480 265-45246-04 480 265-45246-05 480 265-45246-06 
 
 
WARNING 
Recheck and inspect to make certain all components involved in the 
conversion are correct and secure. 
 
Recheck all of the electrical wiring changes made against the wiring diagram requirements for accuracy.  
Check to insure all of the electrical connections are tightly secured and the electrical wire routings are 
orderly.   
 
Special attention should be given to the electrical heating elements.  The wattage and voltage rating of the 
element is marked on the element itself.  Confirm the marking agrees with the intended conversion.  
Additionally, the element wattage can be verified by checking the electrical resistance (ohms of resistance) 
with an Ohm Meter.  This should be done initially before connecting the element to the circuit.  The element 
resistance should be plus or minus 5 percent of the following values: 
 
Table 3. Ohms of Electrical Resistance. 
Voltage Rating of the Element 
Element 
Wattage 
208 volts 
240 volts 
480 volts 
2000 21.6 
28.8 
115.2 
3000 
14.4 19.2 76.8 
4000 
10.8 14.4 57.6 
4500 9.6 
12.8 
51.2 
5000 8.7 
11.5 
46.1 
6000 7.2 
9.6 
38.4