-10. Adjusting the needle bar height 
Reference line (a), which is the second line from the bottom 
of the needle bar (1) (fourth line from the bottom when using 
a DA x 1 needle) should be aligned with the lower edge of 
the needle bar bush D (2) as shown in the illustration when 
the needle bar (1) is at its lowest position. 
1. Turn the machine pulley to set the needle bar (1) to its 
lowest position. 
2.  Remove the oil cap (3). 
3.  Loosen the screw (4) and then move the needle bar (1) up 
or down to adjust its position. 
4.  Securely tighten the screw (4). 
5.  Replace the oil cap (3).
 
 
 
 
 
 
 
 
 
 
 
 
10
-11. Adjusting the needle and feed mechanism timing 
The standard position for point of the needle is as described 
below when the feed dog (1) is lowered from its highest 
position until it is aligned with the top of the needle plate (2). 
(At this time, the “-” mark on the lower shaft will be aligned 
with the center of the scale (4) (“O” mark) on the vertical cam 
(3).) 
<-[][]S / -[][]3> 
The top of the feed dog (1) and the top of the needle plate 
(2) should be aligned, and the point of the needle should 
be approximately 1 mm below the needle plate (2). 
<-[][]5> 
The top of the feed dog (1) and the top of the needle plate 
(2) should be aligned, and there should be a clearance of 
approximately 3 mm between the point of the needle and 
the needle plate (2). 
1.  Tilt back the machine head. 
2.  Loosen the two set screws (5), and then turn the vertical 
cam (3) sligtly to adjust the timing. (Use the “-” mark on 
the lower shaft and the alignment position on the scale (4) 
of the vertical cam (3) as a guide.) 
・ 
To set to the standard position, align the “-” mark on 
the lower shaft with the center of the scale (4) (“O” 
mark) on the vertical cam (3). ([A] in the illustration) 
・ 
To prevent material slippage from occurring, retard the 
needle timing. (Turn the vertical cam (3) in the 
direction of (B). Refer to [B] in the illustration.) 
・ 
To improve thread tightening, advance the needle 
timing. (Turn the vertical cam (3) in the direction of (C). 
Refer to [C] in the illustration.) 
NOTE: Do not turn the vertical cam (3) too far in the 
direction of (C), otherwise it could cause the 
needle to break. 
3. After adjustment is completed, securely tighten the two 
screws (5).   
2286M 
2288M 
4257M 
<-[][]S / [][]3> 
<-[][]5> 
Approx. 1mm 
Approx. 3mm 
(Standard) 
Needle timing is 
advanced 
Needle timing
is retarded 
4256M