Getting Started Guide
N30xx Series Installation
Site Preparation
N30xx Series switches can be mounted in a standard 48.26 cm (19-inch) rack 
or placed on a flat surface.
Make sure that the chosen installation location meets the following site 
requirements:
Power — The switch is installed near an easily accessible 100–240 VAC, 
50–60 Hz outlet. 
Clearance — There is adequate front and rear clearance for operator 
access. Allow clearance for cabling, power connections, and ventilation. 
Cabling — The cabling is routed to avoid sources of electrical noise such 
as radio transmitters, broadcast amplifiers, power lines, and fluorescent 
lighting fixtures. 
Ambient Temperature — The ambient switch operating temperature 
range is 0 to 45ºC (32 to 113ºF) at a relative humidity of up to 95 percent, 
non-condensing.
NOTE: 
Decrease the maximum temperature by 1°C (1.8°F) per 300 m (985 ft.) above 
900m (2955 ft.).
Relative Humidity — The operating relative humidity is 8% to 85% 
(noncondensing) with a maximum humidity gradation of 10% per hour.