Kärcher 600 LP User Manual

Page of 13
WTC 600 LP / MP
9
Maintenance and Care
Version 06/05
Notice: The amount of concentrate will in-
crease. This is correct.
Observe the maximum pressure of 21 bar 
(MP) or 14 bar (LP) at the manometer (11)!
• Repeat the adjustment steps, if required. The 
original drinking water amount may possibly 
not quite be reached.
(3)
The difference between pump and 
concentrate pressure has increased 
by more than _____ bar
• Read the values at the manometer for the 
pump pressure (11) and for the concentrate 
pressure (12), and determine the differential 
pressure.
• Compare the differential pressure with the 
value taken when starting operation (see oper-
ational start-up record).
3.2.6
Mixing the Chemicals
(1)
Metering Table
If the differential pressure has in-
creased by more than _____ bar, then 
the RO filter membrane is clogged. 
Readjustment is no longer possible.
Stop the drinking water production and 
notify the Kärcher Service.
When working with chemicals, always wear protective clothing.
i
Values for the metering of the various chemicals result from the untreated water analysis and 
the system capacity.
Upon starting operation, the Kärcher service technician enters the required metering amounts 
for your equipment into the following metering table.
Metering 
Container
Chemical
Item No.
Metered Amount of the Chemical [ml] per 
10 l Metering Solution
Pre-
chlorination
RM 852 sterilization agent 
*
6.291-772.0
Chlorinated lime 
6.291-505.0
Pre-flocculation Ferrifloc
6.294-703.0
Anti Scalant
RM 5000 hardness stabilizer 6.290-991.0
Post 
chlorination
RM 852 sterilization agent 
6.291-772.0
Chlorinated lime 
6.291-505.0
* These chemicals can each be used alternatively