If a message is displayed
If a message is displayed
If an error or a confirmation message is displayed and 
measurement is stopped in the middle, a trouble may be 
detected during the measurement. Read the message and take 
the proper measure before retrying measurement.
Error message: 
 Take the measure according to the 
message and retry measurement.
Confirmation message:   Check the message content. The 
operation can be continued without 
retrying measurement.
Error messages
"E1 : No Mic" :
The setup microphone is not connected.
➡  Connect the provided setup microphone to the [AUTO 
ROOM EQ MIC IN] jack.
"E2 : Phones" :
Headphones are connected.
➡  Unplug the headphones.
"E3 : No Sp L/R" / "E3 : No Sp L" :
One or both of the front speakers are not connected.
➡  Connect the front speakers properly.
"E3 : No Sp SL" / "E3 : No Sp SR" :
One of the surround speakers is not connected.
➡  Connect the surround speakers properly.
"E3 : No Sp SBL" :
One of the surround back speakers is not connected.
➡  If the system is a 7.1-channel system, connect both the 
surround back left and right speakers. 
If it is a 6.1-channel system, connect the surround back 
speaker to the [SURROUND BACK L] terminal.
"E3 : SB w/o S" :
The surround left and right speakers are not connected.
➡  Connect the surround left and right speakers properly.
"E4 : Noisy" :
The measurement environment is too noisy.
➡  Remove the cause of noise before retrying measurement.
"E5 : Bad S/N" :
The measurement environment is too noisy.
➡  Retry measurement. Do not control the speaker volume 
during measurement.
"E6 : Far SP" :
The speaker is installed too apart.
➡  Reinstall the speaker.
"E7 : DSP" :
A communication error occurred inside the unit.
➡  Retry measurement. If the same error message 
reappears, contact your nearest Kenwood service 
counter.
"E8 : Time Out" :
The measurement took too long time due to a certain 
cause.
➡  Retry measurement. If the same error message 
reappears, contact your nearest Kenwood service 
counter.
KRF-V9300D and KRF-V8300D Speaker setup –"Auto Setup"(Auto Room EQ)–