Mitsubishi Electronics MR-J2S- CL User Manual

Page of 337
13 -  6
13. CHARACTERISTICS
Use the dynamic brake at the load inertia moment indicated in the following table. If the load inertia
moment is higher than this value, the built-in dynamic brake may burn. If there is a possibility that the
load inertia moment may exceed the value, contact Mitsubishi.
Servo amplifier
Load inertia moment ratio [times]
MR-J2S-10CL to MR-J2S-200CL
MR-J2S-10CL1 to MR-J2S-40CL1
30
MR-J2S-350CL
16
MR-J2S-500CL MR-J2S-700CL
15
13.4 Encoder cable flexing life
The flexing life of the cables is shown below. This graph calculated values. Since they are not guaranteed
values, provide a little allowance for these values.
1   10
7
5   10
7
1   10
8
5   10
6
1   10
6
5   10
5
1   10
5
5   10
4
1   10
4
5   10
3
1   10
3
 
a
b
F
lexi
ng l
if
e
 [
ti
m
es]
4
7
10
20
40
70 100
200
Flexing radius [mm]
a :  Long flexing-life encoder cable 
      MR-JCCBL   M-H 
      MR-JHSCBL   M-H 
      MR-ENCBL   M-H 
b :  Standard encoder cable 
      MR-JCCBL   M-L 
      MR-JHSCBL   M-L