Infinity TSS-1100 User Manual

Page of 24
TSS-1100 150W Powered Sub/ Plate Amp 
LINE VOLTAGE
Yes/No
Hi/Lo Line
Nom.
Unit
Notes
US 120vac/60Hz
Yes
108-132
120
Vrms
Normal Operation
EU 230vac/50-60Hz
Yes
207-264
230
Vrms
Normal operation, MOMS required
Parameter
Specification
Unit
QA Test 
Limits
Conditions
Notes
Amp Section
Type (Class AB, D, other)
D
Load Impedance (speaker)
5.6
Ohms
n/a
Nominal
Rated Output Power (120VAC
150
Watts
110
Domestic version only  120 VAC-60 Hz
Rated Output Power (230VAC
150
Watts
110
EU Version only                230 VAC-50 Hz
AVG RMS  Dynamic Power
250
Watts
225
Average RMS power,  3/20 Cycles 50 Hz, Driven
6dB above its input sensitivity sensitivity
THD @ Rated Power
0.5
%
1
22K filter
145 Watts
THD @ 1 Watt
0.1
%
0.5
22K filter
DC Offset
10
mV-DC
30
Amplifier output
Damping factor
>50
DF
20
Measured at amplifier board 
Measured at the amplifier board.  120 Watts @ 
50 Hz, THD must be less tan 0.1%
Input Sensitivity
Input Frequency
35
Hz
35
Nominal Freq.
L&R
188
mVrms
±2dB
To 110 Watts, Ap Zo=600 Ohms
Single input driven
L or R  input
188
mVrms
±2dB
To 110 Watts , Ap Zo=600 Ohms
Single input driven, LFE switch ON
Speaker/Hi Level Input
1.68
Vrms
±2dB
To 120 Watts
Single input driven, LP switch to Normal, This 
applies to 230VAC model only
Signal to Noise
SNR-A-Weighted
90
dBA
85
relative to rated power
A-Weighting filter
SNR-unweighted
85
dBr
80
relative to rated power
22K filter
SNR rel. 1W-unweighted
65
dBr
60
relative to 1W Output
22K filter
Residual Noise Floor
1 mVrms(max)
1.5
Volume @max, w/ A/P Swept 
Bandpass Measurement (Line 
freq.+ harmonics) (BW=20 Khz)
Line level inputs must be terminated using    
1KOHM
Input Impedance
Line Input (L, R,LFE)
10K
ohms
n/a
Nominal
Speaker/Hi Level Input
> 4.7K
ohms
n/a
Nominal
Filters
LP filter 4th order fixed
50-150 Hz
± 10
2nd Order variable and 2nd order fix 2nd order variable + 2nd order fix-24 db/Octave
HP Filter 2nd order
Fixed
LFE Low pass  2nd order
200>LP<1K Hz
LFE input driven only
Notch filter (Friend circuit)
F=61 Hz, Q=3.607, Av=-8.62dB
HP speaker out connector
1st order fix
Left & Right 
200 Hz
± 10
Speaker input  - Spkr out 4 Ohms
(Applies to 230VAC model only)
Left & Right 
100 Hz
± 10
Speaker input  - Spkr out 8 Ohms
(Appies to 230VAC model only)
Limiter 
THD at Max. Output Power
n/a
n/a
functional  Maximum Output Power
Maximum THD as a result of limiting.
Features
--
Volume pot Taper (lin/log)
LOG
--
functional A 
Taper
Speaker input connectors
YES
functional 
L&R Speaker input binding post connectors
HP Speaker out 
YES
functional 
L&R Speaker out with HP applies only to 
230VAC models
Phase switch 
0-180
deg
functional 
LP Filter defeat switch
YES
functional 
Disables LP filter, intended for LFE 
Input Configuration
Line In  (L,R) & LFE
YES
--
functional 
Dual  RCA jack
Spkr/Hi Level In
YES
--
functional 
Binding post  connector L&R (Applies to 
230VAC model only)
Signal Sensing (ATO)
Auto-Turn-On (yes/no)
YES
functional 
ATO Input test frequency
50
Hz
functional 
ATO Level LFE Input
2
mV
functional 
Maximum acceptable level.
ATO Level Speaker in
40
mV
functional 
Maximum acceptable level. (Applies to 230VAC 
model only)
ATO Turn-on time
5
ms
functional 
Amp connected and AC on, then 
input signal applied
Auto Mute/ Turn-OFF Time
15
minutes
18
T before muting, after line or 
speaker level signal is removed
Auto turn of time (T)   must be  5 > T < 18 
Minutes
Power on Delay time
3
sec.
4
AC Power Applied
TSS-1100 
       
 
   
 
      
 
 
 
 
 
         
 
 
2