Infinity TSS-1100 User Manual

Page of 24
Parameter
Specification
Unit
QA Test 
Limits
Conditions
Notes
Transients/Pops
ATO Transient
5 mV-peak
n/a
@ Speaker Outputs
Turn-on Transient
50 mV-peak
2V-pk-pk @ Speaker Outputs
AC Line cycled from OFF to ON
Turn-off Transient
50 mV-peak
2V-pk-pk @ Speaker Outputs
AC Line cycled from ON to OFF
Efficiency
Efficiency
65
%
65
Nominal Line voltage 120 VAC
Stand-by Input Power
18
Watts
20
@ nom. line voltage
Maximum allowable  input power under nominal  
Input voltage and frequency, HOT or COLD 
operation.
Power Cons. @ rated power
170
Watts
180
@ nom. line voltage
120 Watts into 5.6 Ohms @ nominal line voltage
Protections
Short Circuit Protection 
YES
functional  Direct short at output
Amplifier should resume operation after short 
circuit condition removal 
Thermal Protection 
YES
functional
@1/8 max unclipped Power at 1.06 
times the input voltage
Temperature rise in accessible metal parts 
should not exceed 35K rise for domestic version 
or 30K rise for European versions (refer to 
requirements sheet).
DC Offset Protection
YES
-
DC present at Speaker Out leads
Design must insure no Offset at the speaker 
output  under any operating condition including 
abnormal operation
Line Fuse Rating
USA-Domestic 2
Amps
2
Type-T or Slo Blo-250 V
Internal fuse with UL/SEMKO rated holder
EU
1.25
Amps
1.25
Type-T or Slo Blo-250 V, Low 
Breaking capacity
Internal fuse with UL/SEMKO rated holder
TSS-1100 
       
 
   
 
      
 
 
 
 
 
         
 
 
3