Parameter
Specification
Unit
QA Test
Limits
Conditions
Notes
Transients/Pops
ATO Transient
ATO Transient
5 mV-peak
n/a
@ Speaker Outputs
Turn-on Transient
50 mV-peak
2V-pk-pk @ Speaker Outputs
AC Line cycled from OFF to ON
Turn-off Transient
50 mV-peak
2V-pk-pk @ Speaker Outputs
AC Line cycled from ON to OFF
Efficiency
Efficiency
Efficiency
65
%
65
Nominal Line voltage 120 VAC
Stand-by Input Power
18
Watts
20
@ nom. line voltage
Maximum allowable input power under nominal
Input voltage and frequency, HOT or COLD
operation.
Power Cons. @ rated power
170
Watts
180
@ nom. line voltage
120 Watts into 5.6 Ohms @ nominal line voltage
Protections
Short Circuit Protection
YES
functional Direct short at output
Amplifier should resume operation after short
circuit condition removal
Thermal Protection
YES
functional
@1/8 max unclipped Power at 1.06
times the input voltage
Temperature rise in accessible metal parts
should not exceed 35K rise for domestic version
or 30K rise for European versions (refer to
requirements sheet).
DC Offset Protection
YES
-
DC present at Speaker Out leads
Design must insure no Offset at the speaker
output under any operating condition including
abnormal operation
Line Fuse Rating
USA-Domestic 2
Amps
2
Type-T or Slo Blo-250 V
Internal fuse with UL/SEMKO rated holder
EU
1.25
Amps
1.25
Type-T or Slo Blo-250 V, Low
Breaking capacity
Internal fuse with UL/SEMKO rated holder
TSS-1100