Delphi Gateway Systems Analysis INterface Tool (SAINT) User Manual

Page of 20
SAINT
 
Keyword 2000 to RS-232 Gateway                        
01/20/04 
Page 9 of 20 
 
 
4.3.2 
Gateway Reports 
The gateway will report a Reset whenever one occurs.  Most likely causes of reset are power on reset, host 
commanded reset, or gateway micro watchdog error.  The gateway does a cold start on all resets (all information is 
lost). The gateway will also report error conditions with the Report Error message below.  See section 4.3.2.1 for 
error code definitions.  
The gateway will also echo back all system commands.  
Header 
ID 
Description 
Data Bytes 
08h 
80h 
Reset Occurred 
None 
08h 
82h 
Report Error 
1 byte Error Code 
08h 
86h 
Report Time Stamp Information OFF 
None 
08h 
87h 
Report Time Stamp Information ON 
None 
08h 
88h 
Report Transmit Echo ON  
None 
08h 
F0h 
Report Gateway Trigger ON 
None  
08h 
F1h 
Report Gateway Trigger OFF 
None 
4.3.2.1 
Gateway Error Codes 
Most error codes are related to sending data at the wrong rate (usually too fast). 
Code 
Description 
80h 
System - Invalid message ID  
81h 
System - RS-232 Transmit Buffer Full 
82h 
System - UART Error (Overrun, etc.) 
83h 
System – Received message is too long. 
84h 
System - Have not read previous message