Sony HVR-1500 User Manual

Page of 111
53
Recording Timecode and User Bit Data
  Cha
p
te
 Using
 Time
 Da
ta
Synchronizing the Internal Timecode 
Generator to an External Timecode 
— External Synchronization
External regen mode
You can synchronize the internal LTC (Timecode signal 
connected to the TC IN connector, VITC signal inserted in 
the video signal, or RP188 LTC signal superimposed on 
SDI signal) generator to an external timecode (LTC) input 
to this unit. Use this method when synchronizing the 
timecode generators of multiple recorders, when recording 
the playback timecode of an external VCR, or when you 
want to record without interfering with the timecode 
relation of a source image.
When an external timecode is input, the internal timecode 
generator advance mode and frame count mode are 
automatically set as follows.
Advance mode: FREE RUN
Frame count mode: same as the external timecode (drop-
frame or non-drop-frame )
Proceed as follows.
1
Depending on the type of external timecode, set the 
signal input source and TIME CODE menu item (see 
page 77)
 as follows.
1)Select the video signal input with the INPUT SELECT buttons (see 
page 14) in the video/audio input selection section.
2)SDI embedded TC only supports LTC. If SDI input is selected, the 
synchronization priority sequence of external timecode is as follows.
1
 RP188 (embedded LTC)
2
 An Input to the TC IN connector
When the timecode generator is in the regenerate mode 
(when the setting of the TC MODE menu item is INT 
REGEN or EXT REGEN), you can select whether to 
regenerate both timecode and user bit data, or to regenerate 
either one of them, in the TIME CODE >TCG REGEN 
menu item (see page 78).
• When the input mode is i.LINK (the i.LINK indication 
appears in the video area of the input signal display), if 
you set the TC MODE menu item to EXT REGEN, then 
the internal timecode generator is synchronized to the 
i.LINK input and not to the TC IN input.
• External synchronization to VITC is only supported 
when the recording format of this unit is DVCAM.
• When the TC MODE menu item is set to EXT REGEN, 
and timecode is also input from an external device 
connected to the  HDV/DV connector, if the input 
timecode includes discontinuities, or advances 
incorrectly, the input timecode and the timecode to be 
recorded on the tape may be out of step with the 
timecode display on this unit. Also, when using a 
recorded tape with timecode discontinuous in this way, 
editing and search operations may not perform correctly 
depending on the combination of equipment.
To check that an external synchronization 
is present
Press the STOP button to put this unit in stop mode, then 
press the REC button.
Watch the time counter display, and check that the value 
agrees with the external timecode value.
To record VITC
To record VITC on a tape, set the TIME CODE >VITC 
menu item to ON, and carry out recording (even if VITC is 
set to OFF, any VITC signal included in input video is 
recorded unchanged).
Note
External 
timecode and 
input source
Video signal 
input source
1)
Menu settings on 
this unit
TC 
MODE
TC 
SELECT
LTC input to TC 
IN connector
Analog video 
input connector 
or SDI IN 
connector
EXT 
REGEN
TC
LTC in HDV/DV 
signal
 
HDV/DV 
connector
LTC in SDI 
signal 
(RP188)
 2) 
SDI IN 
connector
VITC in video 
signal
Analog video 
input connector 
or SDI IN 
connector
EXT 
REGEN
VITC
VITC in HDV/
DV signal
 HDV/DV 
connector
Notes