Novatel DL-V3 User Manual

Page of 208
DL-V3 User Manual Rev 3
 129
B.31 METTEMP
Specify Air Temperature
The mettemp command allows you to specify ambient temperature. Temperature specified with the 
mettemp command does not affect receiver operation. Rather, it allows you to create a record of 
atmospheric conditions for post-processing purposes.
The mettemp set command specifies air temperature at temp. This command only stores the 
temperature in volatile memory, and does not automatically generate a record. The temperature can 
then be displayed/recorded by requesting the met log.
The mettemp clear and the mettemp default commands clear the temperature setting.
The mettemp default command clears the temperature setting.
Syntax
mettemp set [temp]
mettemp default|clear
Message ID = 165
 Table 51:  METTEMP Default Configuration
Field
Data
Value Used if 
Not Specified
Bytes
Format
Units
Offset
1
Header
-
-
0
2
Parameter Update, see Table 34 
on Page 107
4
Enum
none
H
3
Temperature
0
4
Float
Celsius or 
Fahrenhei
a
a. You may use Celsius or Fahrenheit in your float input, depending on your preference
H+4
Parameter
Power-On
Freset
Stored in NVM
metpress
clear
clear
NO