Silicon Image 141B User Manual
SiI 141B SiI-DS-0037-C
Silicon Image, Inc.
2
Subject to Change without Notice
Functional Block Diagram
Absolute Maximum Conditions
Note: Permanent device damage may occur if absolute maximum conditions are exceeded.
Functional operation should be restricted to the conditions described under Normal Operating Conditions.
Symbol
Parameter
Min
Typ
Max
Units
V
CC
Supply
Voltage
3.3V
-0.3
4.0
V
V
I
Input
Voltage
-0.3 V
CC
+ 0.3
V
V
O
Output
Voltage
-0.3 V
CC
+ 0.3
V
T
A
Ambient Temperature (with power applied)
-25
105
°
C
T
STG
Storage
Temperature
-65
150
°
C
θ
JA
Thermal Resistance (Junction to Ambient)
45
°
C /W
Normal Operating Conditions
Symbol
Parameter
Min
Typ
Max
Units
V
CC
Supply
Voltage
3.0 3.3 3.6 V
V
CCN
Supply
Voltage
Noise
100 mV
P-P
T
A
Ambient Temperature (with power applied)
0
25
70
°
C
DC Digital I/O Specifications
Under normal operating conditions unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ
Max
Units
V
IH
High-level Input Voltage
2
V
V
IL
Low-level
Input
Voltage
0.8
V
V
OH
High-level
Output
Voltage 2.4
V
V
OL
Low-level Output Voltage
0.4
V
V
CINL
Input Clamp Voltage
1
I
CL
= -18mA
GND -0.8
V
V
CIPL
Input Clamp Voltage
1
I
CL
= 18mA
IVCC + 0.8
V
V
CONL
Output Clamp Voltage
1
I
CL
= -18mA
GND -0.8
V
V
COPL
Output Clamp Voltage
1
I
CL
= 18mA
OVCC + 0.8
V
I
IL
Input Leakage Current
-10
10
µ
A
Note:
1
Guaranteed by design. Voltage undershoot or overshoot cannot exceed absolute maximum conditions
for a pulse of greater than 3 ns or one third of the clock cycle.
INTER-
CHANNEL
SYNC.
DECODER
CLT3
CLT2
DE2
CLT1
PLL_SYNC
DE1
VSYNC
HSYNC
DE0
8
8
8
VCR
EXT_RES
PANEL
INTER-
INTER-
FACE
LOGIC
Q[35:0/23:0]
ODCK
DE
HSYNC
VSYNC
CLT1
CLT2
CLT3
RX2+
RX2-
RX1+
RX1-
RX0+
RX0-
RXC+
RXC-
PIXS
OCK_INV
PLL
24/36
VCR
VCR
VCR
DFO
ST
SCDT
PDO
DATA
RECOVERY
CH2
DATA
RECOVERY
CH0
DATA
RECOVERY
CH1
HSYNC_DEJTR
Termination
Control