Andrew L4TDM-PS User Manual

Page of 3
  
Environmental Specifications 
Operating Temperature 
­55 °C to +85 °C (­67 °F to +185 °F) 
Storage Temperature 
­55 °C to +85 °C (­67 °F to +185 °F) 
Immersion Depth 
1 m 
Immersion Test Mating 
Unmated 
Immersion Test Method 
IEC 60529:2001, IP68 
Water Jetting Test Mating 
Unmated 
Water Jetting Test Method 
IEC 60529:2001, IP66 
Moisture Resistance Test Method 
MIL­STD­202F, Method 106F 
Mechanical Shock Test Method 
MIL­STD­202, Method 213, Test Condition I 
Thermal Shock Test Method 
MIL­STD­202F, Method 107G, Test Condition A­1, Low Temperature ­55 °C 
Vibration Test Method 
IEC 60068­2­6 
Corrosion Test Method 
MIL­STD­1344A, Method 1001.1, Test Condition A 
  
Standard Conditions 
Attenuation, Ambient Temperature 
20 °C   |   68 °F 
Average Power, Ambient Temperature  40 °C   |   104 °F 
R e t u r n   L o s s
Frequency Band
VSWR
Return Loss (dB)
45–1000 MHz
1.02
39.00
1010–2200 MHz
1.03
37.00
2200–3000 MHz
1.05
33.00
3010–4000 MHz
1.07
29.00
4010–6000 MHz
1.11
26.00
6010–8000 MHz
1.15
23.00
Regulatory Compliance/Certifications
Agency
Classification
RoHS 2002/95/EC
Compliant by Exemption
China RoHS SJ/T 11364­2006
Above Maximum Concentration Value (MCV)
 
 
Footnotes
Immersion Depth 
Immersion at specified depth for 24 hours 
Insertion Loss, typical 
0.05√¯freq (GHz) (not applicable for elliptical waveguide) 
Product Specifications
L4TDM-PS
©2010 CommScope, Inc. All rights reserved.
All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope.All specifications are subject to change. 
See www.commscope.com/andrew for the most current information.
page 3 of 3