WATER PIPING
HOTTER  WATER  CAN  SCALD: 
Water heaters are intended to produce hot water.  Water heated to a 
temperature which will satisfy space heating, clothes washing, dish 
washing, cleaning and other sanitizing needs can scald and permanently 
injure you upon contact.  Some people are more likely to be permanently 
injured by hot water than others.  These include the elderly, children, the 
infi rm, or physically/mentally handicapped.  If anyone using hot water in 
your home fi ts into one of these groups or if there is a local code or state 
law requiring a certain temperature water at the hot water tap, then you 
must take special precautions.  In addition to using the lowest possible 
temperature setting that satisfi es your hot water needs, a means such 
as a *mixing valve, should be used at the hot water taps used by these 
people or at the water heater, see Figure 15. Valves for reducing point of 
use temperature by mixing cold and hot water are also available:
 
FIGURE 15.
Consult Sears Service Center.  Follow  manufacturer’s instructions for 
installation of the valves.  Before changing the factory setting on the 
thermostat, read the “Temperature Regulation” section in this manual.
This water heater shall not be connected to any heating system or 
component or used as a non-potable water heating appliance.
All piping components connected to this unit shall be suitable for use with 
potable water.
Toxic chemicals, such as those used for boiler treatment shall not be 
introduced into this system.
When the system requires water at temperatures higher than required for 
domestic water purposes, a tempering valve must be installed.  Please 
refer to Figure 15 for suggested piping arrangement.
Water supply systems may, because of such events as high line pressure, 
frequent cut-offs, the effects of water hammer among others, have 
installed devices such as pressure reducing valves, check valves, back 
fl ow preventers, etc. to control these types of problems.  When these 
devices are not equipped with an internal by-pass, and no other measures 
are taken, the devices cause the water system to be closed.  As water is 
heated, it expands (thermal expansion) and closed systems do not allow 
for the expansion of heated water.
The water within the water heater tank expands as it is heated and 
increases the pressure of the water system.  If the relieving point of the 
water heater’s temperature-pressure relief valve is reached, the valve will 
relieve the excess pressure.  The temperature-pressure relief valve is 
not intended for the constant relief of thermal expansion.
 This is an 
unacceptable condition and must be corrected.
It is recommended that any devices installed which could create a closed 
system have a by-pass and/or the system have an expansion tank to 
relieve the pressure built by thermal expansion in the water system.  
Thermal expansion tanks are available from Sears stores and through 
the Sears Service Centers. Contact the local plumbing inspector, water 
supplier and/or the Sears Service Center for assistance in controlling 
these situations.
NOTE:  To protect against untimely corrosion of hot and cold 
water  fi ttings, it is strongly recommended that di-electric unions 
or couplings be installed on this water heater when connected to 
copper pipe.
Figure 16 shows the typical attachment of the water piping to the 
water heater.  The water heater is equipped with 3/4 inch NPT water 
connections.
NOTE: If using copper tubing, solder tubing to an adapter before 
attaching the adapter to the cold water inlet connection.  Do not 
solder the cold water supply line directly to the cold water inlet.  It 
will harm the dip tube and damage the tank.
•   Look at the top cover of the water heater. The water outlet is marked 
“HOT”. Put two or three turns of tefl on tape around the threaded end 
of the threaded-to-sweat coupling and around both ends of the 3/4” 
NPT threaded nipple. Using fl exible connectors, connect the hot water 
pipe to the hot water outlet on the water heater.
•  Look at the top of the water heater. The cold water inlet is marked 
“COLD”. Put two or three turns of tefl on tape around the threaded 
end of the threaded-to-sweat coupling and around both ends of the 
3/4” NPT threaded nipple. Using fl exible connectors, connect the cold 
water pipe to the cold water inlet of the water heater.