Faber M1600 User Manual

Page of 127
 
Genie Monochrome Series-GigE Vision Camera 
Operational Reference    51 
Strobe and General Outputs 
Genie provides two sets of opto-coupled outputs (see 
). These can be used as a strobe 
signal to control lighting or to generate programmable pulses when specific events are generated by the camera. 
They can also be set to a static state (close or open) by the application. 
See 
"
" on page 90
 for connector pinout and electrical information.  
General Outputs: Settings via CamExpert 
The Output Settings dialog box allows you to configure the event mode for both output 1 and output 2. Each 
output can be set independently to one of the available event modes. A typical usage of output is to control a strobe 
light in relation to the camera exposure. Select the output to configure by clicking on the Output 1 or Output 2 
buttons located at the top of the dialog box. Use the Event mode drop-down list box to select the required event 
mode.  
 
The following event modes are available: 
•  Open (default) 
•  Close 
•  Strobe On: Start of Exposure (used for strobe pulse) 
•  Pulse On: Valid Trigger 
•  Pulse On: Invalid Trigger 
•  Pulse On: Start of Readout 
•  Pulse On: End of Readout 
•  Pulse On: End of Acquisition 
•  Pulse On: Input 1 
•  Pulse On: Input 2