Emergency Transfer
Emergency Transfer provides service to and from the local telephone company 
central office (CO) during a power failure or when service is impaired. Emergency 
Transfer is also called Power Failure Transfer; the terms are synonymous.
Detailed description
Emergency Transfer allows analog telephones (500- or 2500-type) to access the 
local CO and to answer incoming calls during a power failure.
Each DEFINITY ECS cabinet supports Emergency Transfer panels via the AUX 
connectors on the rear panel. The transfer is initiated when:
a transfer panel or associated cabinet loses power.
someone manually activates the Emergency Transfer switch on the 
associated maintenance circuit pack
the software determines that service for that cabinet is severely impaired
You cannot activate any other system features during a complete system power 