Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Introduction to the DEFINITY system 
34
Notifying a digital pager of an emergency 
2
Notifying a digital pager of an 
emergency
You also have the option of having your emergency calls go to a digital pager. 
When someone dials an emergency number (for example, 911), the system sends 
the extension and location (that originated the emergency call) to the administered 
pager.
Before you start
You need to administer a 
CRSS-ALRT
 button on at least one of the following.
— Attendant Console (use the 
change attendant
 command)
— Digital telephone set (use the 
change station
 command)
The ARS Digit Analysis Table must have emergency numbers in the Call 
Type column set to 
alrt
 (crisis alert).
You need a digital numeric pager.
You need one of the following circuit packs:
— Call Classifier
— Tone-Clock (with Call Classification and Tone Detection)
Instructions
To set up crisis alert to a digital pager:
1. Type 
change system-parameters crisis-alert
 and press Return.
The 
Crisis Alert System Parameters
 screen appears.
2. In the Alert Pager field, type 
y
.
This allows you to use the Crisis Alert to a Digital Pager feature and causes 
additional crisis alert administration fields to appear.
3. In the Originating Extension field, type a valid unused extension to send 
the crisis alert message.
We’ll type
 7768
.
4. In the Crisis Alert Code field, type 911.
This is the number used to call the crisis alert pager.
5. In the Retries field, type 
5
.
This is the number of additional times the system tries to send out the alert 
message in case of an unsuccessful attempt.