Unibrain 980 User Manual

Page of 72
Unibrain Fire-i 580/780/785/980 Operation Manual 
 
Page 22 
 
 
 
 
Status Control Register 
Address  Name 
Field 
Bit 
Description 
800h 
BRIGHTNESS  Presence_Inq 
 
[0] 
Presence of this feature   
0:N/A  1:Available 
Abs_Control 
[1] 
Absolute value control 
0: Control with value in Value field 
1: Control with value in Absolute value 
CSR if this bit =1, value in Value filed is ignored 
[2..4] 
Reserved 
One_Push 
[5] 
Write ‘1’: begin to work(Self cleared after operation) 
Read : Value=’1’ in operation 
       Value =’0’ not in operation 
If A_M_Mode=1, this bit is ignored 
On/OFF 
[6] 
Write : ON or OFF this feature 
Read : read a status 
0: OFF,   1:ON 
If this bit=0, other fields will be read only.   
A_M_Mode 
[7] 
Write : Set the mode 
Read : Read a current mode 
0: Manual,  1:Auto 
[8..19] 
Reserved 
Value 
[20..31] 
Minimum value for this feature control 
3.2. 
Auto Exposure Control 
The automatic shutter/gain mode is based on a feedback loop which calculates the average pixel luminance. Then the 
average is compared with the exposure reference value, adjusting shutter and gain accordingly. 
Inquiry Register 
Address 
Name 
Field 
Bit 
Description 
504h 
AUTO_EXP
OSURE_INQ 
Presence_Inq 
[0] 
Presence of this feature 
Abs_Control_Inq 
[1] 
Capability of control with absolute value 
[2] 
Reserved 
One_Push_Inq 
[3] 
One  push auto mode(Controlled automatically by 
camera only once) 
ReadOut_Inq 
[4] 
Capability of reading the value of this feature 
On/Off_Inq 
[5] 
Capability of switching this feature On and OFF 
Auto_Inq 
[6] 
Auto mode (Controlled automatically by camera) 
Manual_Inq 
[7] 
Manual mode(Controlled by user) 
Min_Value 
[8..19] 
Minimum value for this feature control 
Max_Value 
[20..31] 
Maximum value for this feature control 
Status Control Register 
Address 
Name 
Field 
Bit 
Description 
804h 
AUTO_EXP
OSURE 
Presence_Inq 
[0] 
Presence of this feature 
0:N/A 1:Available 
Abs_Control 
[1] 
Absolute value control 
0: Control with value in the Value field 
1: Control with value in the Absolute value CSR 
If this bit = 1, value in the Value field is ignored. 
[2..4] 
Reserved 
One_Push 
[5] 
Write ‘1’ :begin to work  (Self cleared after 
operation)