Unibrain 980 User Manual

Page of 72
Unibrain Fire-i 580/780/785/980 Operation Manual 
 
Page 24 
 
 
 
 
Status Control Register 
Address 
Name 
Field 
Bit 
Description 
80Ch 
WHITE_BAL
ANCE 
Presence_Inq 
[0] 
Presence of this feature. 0:N/A 1:Available 
Abs_Control 
[1] 
Absolute value control 
0: Control with value in the Value field 
1: Control with value in the Absolute value CSR 
If this bit = 1, value in the Value field is ignored. 
[2..4] 
Reserved 
One_Push 
[5] 
Write ‘1’ :begin to work(Self cleared after 
operation) 
Read: Value=’1’ in operation 
      Value=’0’ not in operation 
If A_M_Mode =1, this bit is ignored 
ON_OFF 
[6] 
Write: ON or OFF this feature, 
Read: read a status 
0:OFF, 1:ON 
If this bit=0, other fields will be read only. 
A_M_Mode 
[7] 
Write: set the mode, 
Read: read a current mode 
0: Manual, 1:Auto 
[8..19] 
U Value / B_Value. 
Write the value in AUTO mode, this field is 
ignored. 
If “ReadOut” capability is not available,, read 
value has no mean   
Value 
[20..31] 
V Value / R_Value 
Write the value in AUTO mode, this field is 
ignored. 
If”ReadOut” capability is not available, read value 
has no meaning 
 
3.5. 
Hue 
Color models support Hue control which changes the color phase of the picture by adjusting the Green gain.    You may 
use this feature when white balance correction adjusting Red and Blue value does not give satisfying result.