Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1104
M/T-BD (Maintenance/Test Circuit Pack) 
9
M/T-BD (Maintenance/Test Circuit 
Pack)
The Maintenance/Test Circuit Pack supports Packet Bus fault detection and bus 
reconfiguration for the port network in which it is installed. The circuit pack also 
provides Analog Trunk testing, and data loopback testing of DCP Mode 2 
endpoints and Digital (ISDN) Trunk Facilities via the TDM bus.
Port 1 of the Maintenance/Test board is the Analog Test port which provides the 
Analog Trunk testing function for Automatic Transmission Measurement System 
(ATMS). ATMS is a feature in which calls are made from a device called an 
Originating Test Line (OTL) over a specific trunk to a device called a Terminating 
Test Line (TTL). The OTL and TTL can then send tones over the trunk under test 
and determine the quality of the connection. Ports 2 and 3 are the Digital ports 
which provide the Digital (ISDN) Trunk testing functions. Port 4 is the Packet port 
which provides the Packet Bus maintenance function.
Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation for 
circuit pack level errors. See also M/T-ANA (Maintenance/Test Analog Test Port), 
M/T-DIG (Maintenance/Test Digital Port) and M/T-PKT (Maintenance/Test Packet 
Bus Port) Maintenance documentation for related analog test port digital port 
and Packet Bus port information, respectively.
All ports except the Analog port (port 1) of the Maintenance/Test Board are 
automatically administered when the circuit pack is inserted into the system and 
they are removed when the circuit pack is unplugged from the system. The 
Analog port however, is administered via the station screen with the type "105TL" 
for an OTL or a TTL. This port remains administered even after the circuit pack is 
physically removed from the system. Care should be taken to remove the OTL or 
the TTL before unplugging the circuit pack.
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician Command 
to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21).
Full Name of MO
M/T-BD
MIN
test board UUCSS l
Maintenance/Test Circuit Pack
M/T-BD
WRN
release board UUCSS
Maintenance/Test Circuit Pack