Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1105
M/T-BD (Maintenance/Test Circuit Pack) 
9
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. This error indicates that the circuit pack has stopped functioning. Reset 
the circuit pack via busyout board UUCSSreset board UUCSS, and 
release board UUCSS commands. If the SAKI Sanity Test (#53) passes, 
then the on-board circuitry is healthy. If the SAKI Sanity Test (#53) fails, 
replace the circuit pack.
b. The circuit pack has been busied out via the busyout board UUCSS 
command. Execute release board UUCSS command.
Maintenance/Test Board Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
1
1.
Major or Minor alarms on this MO may have been downgraded to Warning alarms based on the values
used in the set options command.
On/Off 
Board
Test to Clear Value
0
2
2.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1(a)
0
SAKI Sanity Test 
(#53)
MINOR
ON
See footnote a
18(b)
0
Busyout Board
WARNING
OFF
release board UUCSS
36(c)
0
217(e)
WARNING
ON
257(d)
0
CC Loop Test (#52)
MINOR
ON
test board UUCSS r3
267(e)
WARNING
ON
513(f)
4352 
to 
4357
769(g)
4358
1025(h)
4363
NPE Audit Test (#50)
test board UUCSS l
1538(i)
0
MINOR
ON
3840(j)
4096 
to 
4101
3999 (k)
Any
None