Barco K5960051-01 User Manual

Page of 256
178    Barco - RHDM-1701 - User manual   
Addendum
The area of measurement is not greater than a circle of diameter 0.1H.
Luminance uniformity on white
White point chromaticity and luminance is calibrated at the center of the display for x=0.3127,
y=0.3290 and Y=100 cd/m
2
 (at level 1019).
The least bright point has a luminance which is equal to or larger than 88% of the luminance
measured in the center of the screen.
Color uniformity on white
White point chromaticity and luminance is calibrated at the center of the display for x=0.3127,
y=0.3290 and Y=100 cd/m
2
 (at level 1019).
For all points the following tolerance requirement applies:
Maximal: 
The tolerances apply for a temperature of 25°C.
Luminance uniformity on black
For all points, the measured luminance value deviates less than 50% from the luminance value
measured at the center point.
7.1.1.3  Power supply specification
7.1.1.3.1
Power inputs
•  AC input voltage:
 
90 - 264 Vac
 
47 - 63 Hz
 
Input current: 3.6 A at 115 Vac and 1.8 A at 230 Vac
 
Inrush current: maximum 14 A at 230 Vac (cold start) / maximum 7 A at 120 Vac (@ 25 °C)
7.1.1.3.2
Power consumption
•  Nominal power consumption: 100 W
•  Maximum power consumption: 115 W
•  Power consumption in hard standby mode: lower than 3 W
•  Power consumption in soft standby mode: typical 65 W
003
.
0
'
'
∆ v
u