145 052
Maintenance Every 125 Service Hours
Checking the Battery and Cable Connections
CAUTION
When working on the electrical equipment,
always disconnect the ground lead (1) of the
battery.
-
Check the battery acid level and inspect the battery
for leaks. Observe the information of the battery
manufacturer.
-
Remove any corrosion on the terminals.
-
Grease the battery terminals with non-acidic battery
grease.
-
Check cables and cable connections for secure
connection and damage.
-
Replace any damaged cables and cable connections.
Checking the High Pressure Hoses
-
Check the high-pressure hoses for cracks, bending
and chafing, and for porous surfaces.
Replace damaged high-pressure hoses immediately.
This work may only be carried out by an authorized workshop.
Bild_153