Holder C 9.72 H User Manual

Page of 221
Operating Instructions
145 052
93
C 9700 ... C 9.88 H
Operating the Implements
Installing the Cardan Shafts
Only use the shafts suited and intended for the implement.
The shafts are supplied with the implement. The length of
the articulated shaft must adjusted before the first
installation. In case of doubt, please contact our customer
service. Observe installation instructions for the articulated
shaft when installing it.
DANGER
Turn off the engine before the installation. After
the installation, fit the protective devices as
specified. After the removal, cover the PTO
shaft  (1) with the protective cap again.
Removing Implements
-
Drive the implement to its storage place and  lower it
with the front lift.
-
Stop the engine, but do not turn off the ignition.
-
Operate all control levers for the front lift several times
in all directions. This relieves the pressure in the hydrau-
lic system.
-
Slide the outer ring of the hydraulic couplings (1) back
and disconnect the hydraulic hoses (2).
-
Close the protective caps of the hydraulic couplings (as
for item 4).
-
Remove the upper link from the pin of the upper link
support.
-
Pull the quick attaches (3) up to release the implement
pins.
-
Lower the front lift and back off.
1
2
3
4
1