17.  Battery Charger Input – This receptacle allows the capability 
to recharge the 12 volt DC storage battery provided with 
the 12 Volt Adaptor Plug Charger which is included in the 
Accessory Box. Located behind the battery charger input is 
a 1.50 Amp in-line fuse which is inside the control panel to 
protect the battery (electric start models only).
18.  Battery – Powers the electric starter (electric start models 
only).
Figure 3 - Generator Controls
Figure 4 - Generator Controls
This is a 120 Volt outlet protected against overload by a 20 Amp 
push-to-reset circuit breaker (Figure 5). Use each socket to power 
120 Volt AC, single phase, 60 Hz electrical loads requiring up to a 
combined 2400 watts (2.4 kW) or 20 Amps of current. Use only 
high quality, well-insulated, 3-wire grounded cord sets rated for 
125 Volts at 20 Amps (or greater).
Keep extension cords as short as possible, preferably less than 
15 feet long, to prevent voltage drop and possible overheating of 
wires.
Figure 5 - 120 Volt AC, 20 Amp, Duplex Receptacle
This is a 120 Volt outlet protected against overload by a 20 Amp 
push-to-reset circuit breaker (Figure 6). Use each socket to power 
120 Volt AC, single phase, 60 Hz electrical loads requiring up to a 
combined 2400 watts (2.4 kW) or 20 Amps of current. Use only 
high quality, well-insulated, 3-wire grounded cord sets rated for 
125 Volts at 20 Amps (or greater).
Keep extension cords as short as possible to prevent voltage drop 
and possible overheating of wires.
Figure 6 - 120 Volt AC, 20 Amp, GFCI Duplex Receptacle