HW4000 Portable Generator Owner’s Manual
www.honeywellgenerators.com
27
Storing Generator
Draining Fuel
1.
Turn fuel lever to OFF position.
2.
Run engine until it stops due to lack of fuel.
3.
Place suitable container underneath drain hole to 
catch fuel.
4.
Loosen bolt (underneath fuel sediment cup).
5.
Turn fuel lever to ON position.
6.
Allow fuel to drain into container.
7.
To ensure all fuel is drained, carefully tip generator by 
pulling up on frame at side opposite of recoil starter 
handle.
8.
Allow fuel to completely drain into container.
9.
When ready to put generator back into operation, refill 
with fresh fuel (see page 22).
FIGURE 37:  
Loosen Bolt to Drain Fuel
FIGURE 38:  
Fuel Valve Lever — ON/OFF position
FIGURE 39:  
Tip Generator to Completely Drain Fuel