Generac Power Systems 5410 User Manual

Page of 82
Section 6
TROUBLESHOOTING FLOWCHARTS
Page 31
CLEAN AND REGAP OR 
REPLACE SPARK PLUG
REPLACE 
BAD 
SWITCH
REPAIR OR 
REPLACE
REPLACE MAGNETOS
ADJUST VALVES
REPLENISH FUEL SUPPLY
O.K.
Problem 7 – Engine Cranks But Will Not Start (LP Units)
(Overcrank Warning Code on SW1 LED – 3 Flashes)
BAD
BAD
BAD
REPAIR OR REPLACE 
AS NECESSARY
BAD
BAD
BAD
GOOD
GOOD
GOOD
GOOD
GOOD
GOOD
TEST 26 – CHECK 
WIRE 14 POWER 
SUPPLY
TEST 20 – CHECK 
START-STOP 
SWITCH
TEST 25 – 
CHECK FUEL 
SUPPLY
TEST 41 – CHECK 
LPG FUEL 
SOLENOID
TEST 29 – 
CHECK 
IGNITION 
SPARK
TEST 31 – CHECK 
AND ADJUST 
IGNITION 
MAGNETOS
TEST 30 – 
CHECK SPARK 
PLUG
TEST 32 – CHECK 
VALVE 
ADJUSTMENT
TEST 35 – CHECK 
ENGINE / CYLINDER 
LEAK DOWN TEST / 
COMPRESSION TEST
CHECK 
FLYWHEEL KEY 
– SEE TEST 31 
ON PAGE 57
LOW LP PRESSURE
WEAK SPARK / NO SPARK / 
INTERMITTENT SPARK
NO START
REPLACE 
PRINTED CIRCUIT 
BOARD