Figure 7-23. – Clamp-On Ammeter
TACHOMETER:
A  tachometer  is  available  from  your  Generac  Power 
Systems source of supply. Order as P/N 042223. The 
tachometer  measures  from  800  to  50,000  RPM  (see  
Figure 7-24).
Figure 7-24. – Tachometer
TEST BRACkET:
A starter motor test bracket may be made as shown in 
Figure 7-25.
METAL STOCk
1/4" THICk STEEL
12"
1.0"
4"
2"
2.625"
3.5"
0.5"
0.5"
DRILL TWO HOLES — 1/2"
FOR STARTER 
MOUNTING BRACkET
DRILL TWO HOLES — 1/2"
FOR MOUNTING TACHOMETER
TAP FOR 1/4-20 NC SCREWS
Figure 7-25. – Test Bracket
REMOVE STARTER MOTOR:
It is recommended that the Starter Motor be removed 
from  the  engine  when  testing  Starter  Motor  perfor-
mance.  Assemble  starter  to  test  bracket  and  clamp 
test bracket in vise (Figure 7-26).
TESTING STARTER MOTOR:
1.  A fully charged 12 volt battery is required.
2.  Connect jumper cables and clamp-on ammeter as 
shown in Figure 7-26.
3.  With the Starter Motor activated (jump the termi-
nal  on  the  Starter  Contactor  to  battery  voltage), 
note  the  reading  on  the  clamp-on  ammeter  and 
on the tachometer (rpm).
Note: Take the reading after the ammeter and 
tachometer  are  stabilized,  approximately  2-4 
seconds.
4.  A starter motor in good condition will be within the 
following specifications:
Minimum rpm
4500
Maximum Amps
50
Note: Nominal amp draw of starter in generator is 
60 amps.
STARTER
CONTACTOR
STARTER
MOTOR
TACHOMETER
12 VOLT
BATTERY
CLAMP ON
AMP METER
VISE
Figure 7-26. – Testing Starter Motor Performance