Revolabs 01-hdvenu User Manual

Page of 26
 
- 21 - 
Power Module 
The Charger Base requires 5VDC power, provided by the AC Adapter. Plug the supplied AC adapter 
into  an  appropriate  power  outlet  110-240  AC,  50-60Hz.  The  power  LED  on  the  Charger  Base  will 
illuminate. 
 
Charging the Microphone Batteries 
 
First-time  use 
—  Before  using  the  wireless  microphone  the  first  time,  charge  the  batteries  in  the 
microphones for eight hours (or overnight) in the Charger Base. 
 
Recharging 
— When the YELLOW LED starts to flash intermittently on the microphone the battery 
has 30 minutes of charge remaining. Over time (years), batteries gradually wear down and will result 
in shorter run times. This is normal. Always return microphones to the Charger Base when not in use. 
ImportantThe Lithium Polymer rechargeable batteries that power the microphones are not user 
serviceable. Please contact Revolabs (www.revolabs.com) or your AV service provider for 
replacement instructions and to assure the proper disposal method is used. Warning: Never 
dispose of batteries in a fire because they may explode.
 
Either a solid RED LED (charging) or solid GREEN LED (100% charged) will appear to confirm that 
the microphone is inserted properly in the Charger Base. The microphones are not transmitting audio 
to  the  HD  Base  Station  while  in  the  Charger  Base.  In  normal  use,  batteries  should  fully  charge  in 
about 2 hours, 
but will ―quick-charge‖ to 80% capacity in approximately 1 hour and 20 minutes. Fully 
charged microphones left in the Charger Base remain solid GREEN. 
 
Updating the Revolabs HD
TM
 Firmware 
 
Revolabs  HD
TM
  Systems  are  field  upgradable  for  the  firmware  portion  of  the  Base  Station  and 
microphones.  The  firmware  must  be  sent  to  the  Base  station  using  the  Revolabs  HD  Panel.  The 
software can be downloaded a
. 
 
Updating the HD Venue Base Station and HD Microphones 
 
1.  Connect to the Base Station using the mini-USB cable. 
2.  Pair both mics to the Base Station and make sure they are out of the Charger Base. 
3.  Start the Revolabs HD Control Panel software 
4. 
Select the ―Firmware‖ button on the Control Panel 
5.  Choose the desired firmware version from the location it was saved during download. 
6.  Choose whether you would like to update the Base Station, Mics, or Both.  
7.  Select OK. The Revolabs HD Firmware Loader will notify you when complete. 
 
The  HD  Microphone  firmware  updates  wirelessly  during  the  firmware  process  as  long  as  the 
microphones  are  out  of  the  Charger  Base,  paired  to  the  Base  Station,  and  communicating  with  the 
Base Station.