Vocopro CLG-600 User Manual

Page of 16
8
Front Panel Description and Controls 
(cont.)
4. IN/OUT button - This switch enables you to quickly 
hear the CLG-600 compressor/limiter IN or OUT of the 
audio chain. When the switch is in the OUT position, 
all limiting and compression controls and functions 
are bypassed, with the exception of the gain and 
output controls, which continue to function as 
straightforward level controls.
5. THRESHOLD control - The THRESHOLD control 
has a range of -40dB to +20 dB, allowing applications 
from low level compression to high level limiting. The 
THRESHOLD control determines the audio level above 
which GAIN REDUCTION occurs. When the 
THRESHOLD LED comes on, that means that GAIN 
REDUCTION is beginning to occur, due to input signal 
peaks exceeding the selected threshold in dB.
6. RATIO control - This control determines the RATIO 
of change in output level to changes in input level 
for all signals above threshold. The numbers printed 
around the RATIO control are calibrated in dB and 
indicate the increase in input (above threshold) 
required to produce a 1db increase in output. This 
can be expressed conveniently as a ratio. If the 
output remains constant no matter how high the 
input level, we have an infinite input/output ratio. 
NOTE: It should be remembered that the RATIO 
control has no effect on signals which are below 
threshold
. There is a common but incorrect 
notion that limiting always implies the use of an 
infinite ratio. Although there are times when an 
infinite ratio is desirable, there will be situations 
where infinite, or "hard", limiting action is neither 
appropriate nor necessary.
7. ATTACK control - ATTACK controls how fast the 
compressor reacts to signals passing over the 
threshold point. The available range is from 0.1 to 
200 ms. This control when used correctly creates 
either a smooth or abrupt signal process.
8. RELEASE control  - The RELEASE control 
determines how fast or slow a compressed 
segment returns to its original volume. The 
available range is from .05 to 4 seconds. This 
control when used correctly creates either a 
9. AUTO/MANUAL switch - By activating the AUTO 
switch to the ON position, the attack and release 
controls are handled by the CLG-600 
automatically.  When it is set to the MANUAL 
position, the attack and release controls will 
adhere to settings of the controls in place. This 
allows for unobtrusive musical compression with 
widely varying dynamics to occur without 
"manning" the sound system.
10. OUTPUT LEVEL control - OUTPUT Level control 
is provided to fully cut or restore up to -/+ 20 dB 
of system gain. For unity gain, set the control to 0. 
NOTE:
 
When the unit is in the BYPASS mode the 
output
 control still functions.
11. GAIN REDUCTION meter - This 8-stage LED 
meter indicates the actual GAIN REDUCTION 
processing level and displays this in range 
of 0-30 dB.
12. LEVEL EXPANSION meter - This 8-stage meter 
indicates the actual LEVEL EXPANSION level and 
displays this in a range of -30dB to +6dB.
LEVEL
THRESHOLD
dB
MANUAL
AUTO
COMPRESSOR/LIMITER
RATIO
M1
RELEASE
Sec
O U P U T
dB
CH 1
            30        27        24        21        18        15        12         9          6          4          2           1 
GAIN
OUT
 -30        20        -10        -5         -3          0         +3        +5
+20
+10
0
-10
-20
-30
-40
2.5
1
1.5
8
200
2.5
0.1
4
.05
0.5
-20
+20
0
OFF
msec
IN
4
5
6
7
8
9
10
11
12