Edirol UA-1000 User Manual

Page of 56
 
29
Basic connections and settings
 
Recording onto an external ADAT device
 
fig.adat-out
 
 
Connections
 
Connect an optical cable from the OPTICAL OUT jack.
 
 
Sampling frequency select switch
 
Select either 44.1 kHz or 48 kHz.
 
 
ADAT mode switch
 
Press the 
 
ADAT mode switch
 
 to turn it on.
 
* By pressing the 
 
external clock mode switch
 
 in ADAT mode, you can use ADAT Output mode to 
synchronize the word clock or digital input to an external device.
Optical cable
INPUT
OPTICAL OUT
If you turn on the external synchronization mode switch when using ADAT output mode, the output to the 
ADAT will be synchronized to the word clock from the external device or to the clock of the digital input.
fig.adat-out2
* If the word clock input connector and the digital input connector are both connected, the word 
clock input connector
 will take priority for synchronization.
INPUT
OPTICAL OUT
WORD CLOCK IN
UA-1000_e.book 29 ページ 2003年8月6日 水曜日 午前11時52分