General Information 
14
312775G
General Information
Reference numbers and letters in parentheses in 
the text refer to numbers and letters in the illustra-
tions.
. 2, page 10, shows the basic components of a 
manual system. Contact your Graco distributor for 
actual system designs.
Be sure all accessories are adequately sized and 
pressure-rated to meet system requirements.
There must be a shutoff valve between each fluid 
supply line and the ProMix system.
A 100 mesh minimum fluid filter must be installed on 
component A and B fluid supply lines.
To protect the EasyKey screens from paints and 
solvents, clear-plastic protective shields are avail-
able in packs of 10 (Part No. 197902). Clean the 
screens with a dry cloth if necessary.
Wall Mounting
page 32.
2. Ensure that the wall and mounting hardware are 
strong enough to support the weight of the equip-
ment, fluid, hoses, and stress caused during opera-
tion.
3. Using the equipment as a template, mark the 
mounting holes on the wall at a convenient height 
for the operator and so equipment is easily accessi-
ble for maintenance. 
4. Drill mounting holes in the wall. Install anchors as 
needed.
5. Bolt equipment securely.
Air Supply
Requirements
Compressed air supply pressure: 75-100 psi 
(517-700 kPa, 5.2-7 bar).
Air hoses: use grounded hoses that are correctly 
sized for your system.
Air regulator and bleed-type shutoff valve: 
include in each air line to fluid supply equipment. 
Install an additional shutoff valve upstream of all air 
line accessories to isolate them for servicing.
Air line filter: a 10 micron or better air filter is rec-
ommended to filter oil and water out of the air supply 
and help avoid paint contamination and clogged 
solenoids. See F
Trapped air can cause a pump or dispense valve to 
cycle unexpectedly, which could result in serious injury 
from splashing or moving parts. Use bleed-type shutoff 
valves.