Fluid Supply 
16
312775G
Fluid Supply
Requirements
ProMix models are available to operate air spray or 
air-assisted systems with a capacity of up to 3800 
cc/min. 
Fluid supply pressure tanks, feed pumps, or circu-
lating systems can be used. 
Materials can be transferred from their original con-
tainers or from a central paint recirculating line.
For an airless system, the user must supply a gun 
trigger signal to the ProMix 2KS.
See manual 313599 for Coriolis meter installation 
and operation instructions.
If you are using dynamic dosing, see Fluid Connec-
tions
 at right and also seSetup the Fluid Mani-
fold for Dynamic Dosing
 on 
page 18.
NOTE: The fluid supply must be free of pressure spikes, 
which are commonly caused by pump stroke change-
over. If necessary, install pressure regulators or a surge 
tank on the ProMix fluid inlets to reduce pulsation. Con-
tact your Graco distributor for additional information.
Fluid Connections
1. Connect the solvent supply lines.
a. Connect the solvent supply line to the 1/4 npt(f) 
solvent purge valve inlet. See F
b. Multiple color system: also connect a solvent 
supply line to the color change stack (Q), top 
valve 4 or 5. See F
. 7. 
NOTE: Solvent supplied by a single source can cause 
cross contamination and damage to the system. Install 
check valves or use separated solvent sources.
2. Connect the component A supply line(s).
Single color system: connect component 
supply line to the component A flow meter 
inlet.
Multiple color system: connect compo-
nent A supply lines to the color change 
valve stack (S) inlets. See F
. 7. The color 
number is marked on the valve air supply 
line.
NOTE: Paint Recirculating System Only
The color change valves have two fluid 
ports for each individual valve. If you are 
recirculating paint, plumb the valves in one 
port and out the other.
Another option is to use a tee fitting to recir-
culate.
NOTE: Verify that all unused fluid ports on the color 
change valve stack are plugged before operation. An 
open port will leak fluid.
3. Connect the component B line to the component B 
flow meter inlet.
NOTE: The component A and B fluid meter inlets have 
fluid check valves to prevent backflow from fluid supply 
pressure fluctuations. Backflow can cause ratio inaccu-
racies.
4. Connect the gun fluid supply line between the fluid 
manifold static mixer outlet and the gun fluid inlet.
Do not exceed the pressure rating of the lowest rated 
component. See the identification label (F
IG
. 1 on page 
4).
To reduce the risk of injury, including fluid injection, 
you must install a shutoff valve between each fluid sup-
ply line and the fluid manifold assembly. Use the 
valves to shut off fluid during maintenance and service.