Agilent Technologies A.18.00 User Manual

Page of 581
476
S:\agilent\8920\8920b\PRGGUIDE\BOOK\CHAPTERS\callproc.fb
 
Chapter 8, Programming the Call Processing Subsystem
CALL DATA Screen Message Field Descriptions
Local
This field displays the local control field. This field is specific to each system. The 
ORDER
 field must be set to local control for this field to be interpreted by the Test 
Set.
ORDQ
This field displays the received order qualifier. The field qualifies the order confirmation 
to a specific action.
Order
This field displays the 
Order
 field and identifies the order type received by the 
Test Set.
RSVD
Reserved for future use.
Parity
This field displays the parity of the received data.
Querying a Single Field
Example of Querying A Single Field
OUTPUT 714;"CALLP:DATA ’RECCW A’"
OUTPUT 714;"CALLP:RECA:SCM?"
ENTER 714;Scm$
PRINT Scm$ 
Example Printout
"1110"