Chapter 8, Programming the Call Processing Subsystem
CALL DATA Screen Message Field Descriptions
Querying Multiple Fields With Single OUTPUT/ENTER
When multiple queries are combined into one command string the Test Set 
responds by sending one response message containing individual response 
message units separated by a response message unit separator (;).
Example of Multiple Queries Combined Into One Command String
OUTPUT 714;"CALLP:RECA:NAWC?;SER?;EXT?;SCM?;MIN?"
OUTPUT 714;"CALLP:DATA ’RECCW A’"
ENTER 714;Message$ 
PRINT Message$ 
Printed Test Set Response Message
"010";"1";"1";"1110";"110111100101101111010101"
In order to read individual response message units into individual string variables 
combined into one ENTER statement the programming language used must 
recognize the response message unit separator (;) as an entry terminator for each 
string in the input list. If the programming language used cannot recognize the 
response message unit separator (;) as an entry terminator then the response 
message must be read into one string and individual responses parsed out.