Toro 53769 User Manual

Page of 12
Installation Procedure
v
 Adjust Rain Sensitivity:
 The sensitivity setting determines the amount of 
rainfall required to trigger the RainSensor and suspend automatic watering. 
The RainSensor is factory-set at 6mm. Prior to installing the RainSensor, adjust 
the rainfall sensitivity as preferred to one of four optional settings as indicated in 
Figure 2
.
To adjust, turn the cap slightly to disengage the pins 
from the current setting. Adjust the cap up or down to 
the preferred slot position, then re-engage the pins. 
Note: 
Make sure the slot is correctly aligned with the pin 
when making an adjustment. Do not force the cap into 
position.
Note:
 The 3mm setting is not recommended for loca-
tions where high-humidity is common.
v
 Set Sensor Operation Mode (Applies to Model 53769, RainSensor Only):
 
The RainSensor is preset for normally-closed sensor operation, but can be 
easily converted to normally-open if needed. Prior to installation, determine 
whether your automatic timer requires a normally-closed or normally-open sen-
sor by referring to the timer user’s guide. If a normally-open sensor is required 
(for example, when used with a Toro ECx
TM
 or GreenKeeper
®  
timer), configure 
the RainSensor as shown in Figure 3.
Model 53853 only:
 If using the Freeze version, model 53853, and your 
controller requires Normally Open Sensor operation, the sensor connection can 
not be used. Instead, refer to the wiring configuration B and C under “Connect 
RainSensor Wiring
” section.
1.  Using a small screwdriver, release and 
remove the access cover by depressing 
the two retaining tabs. Slide the control 
board assembly out of the housing.  
See Figure 3.
2.  Carefully remove the wire connector from 
the left pin of the microswitch and attach it 
to the center pin. Leave the right wire  
connected.
3.  Slide the control board back into the  
housing making sure it is properly aligned. 
Install the access cover with the connection 
wire knot on the inside the housing.
6mm
13mm
25mm
19mm
3mm
Figure 2
Normally Open
Normally Closed
Figure 3