Toro 53769 User Manual

Page of 12
v
 Connect RainSensor Wiring:
Route the RainSensor connection wire into the timer through the access hole in 
the base of the timer cabinet.  
Note:
 Avoid routing the wire over any sharp edges where damage to the wire 
insulation may occur. For best results, hide the wire as  much as possible by 
tucking it under shingles and/or moldings. Seal any holes made by passing the 
wire through structure walls.
 
Caution: To prevent severe equipment damage, never connect the 
RainSensor to any power source greater than 24 VAC. If you are in doubt, 
contact a qualified installer or electrician.
1. 
Disconnect power to the timer.
2. 
Use one of the following connection methods AB or C, that best suits the 
timer model configuration.
•  Find the controller sensor terminals (generally marked “SENSOR”, “SEN”  
or “S”) and attach the RainSensor control wires directly to these terminals  
(in either order).
Note:
 There may be a jumper wire connecting the two Sensor wire terminals 
that must be removed when connecting the RainSensor. Also, place the Sensor 
Bypass switch in the Active position for sensor-controlled operation. 
• Remove the valve common wire(s) from the valve common wire terminal and 
join to one RainSensor wire lead using a twist-on wire connector. Attach the 
remaining RainSensor wire lead to the valve common terminal.
Common Wire From Valves
Timer with Sensor terminals, with or without pump start/
master valve:
A
Sensor Bypass Switch
Common Wire From Valves
To Valves
Twist-on Wire Connector
Irrigation System Timer
Timer without Sensor terminals or pump start/ master 
valve:
B
To Valves