Fisher 244ER User Manual

Page of 64
Rosemount Models 244EH and 244ER PC-Programmable Temperature Transmitters
2-8
Rail Mount Transmitter with Threaded Sensor
The least complicated assembly uses:
• a threaded sensor with flying heads
• a threaded sensor connection head
• a union and nipple extension assembly
• a  threaded  thermowell
Refer to Volume 1 of the Rosemount Sensors Product Data Sheet 
(document number 00813-0100-2654) for complete sensor and 
mounting accessory information.
To complete the assembly, follow the procedure described below.
1. Attach the transmitter to a suitable rail or panel.
2. Attach the thermowell to the pipe or process container wall. Install 
and tighten the thermowell before applying pressure.
3. Attach necessary extension nipples and adapters. Seal the nipple 
and adapter threads with silicone tape.
4. Screw the sensor into the thermowell. Install drain seals if 
required for severe environments or to satisfy code requirements.
5. Screw the connection head to the sensor.
6. Attach the sensor lead wires to the connection head terminals.
7. Attach additional sensor lead wires from the connection head to 
the transmitter.
8. Attach and tighten the connection head cover. Enclosure covers 
must be fully engaged to meet explosion-proof requirements.
9. Set the transmitter failure mode switch
10. Attach the sensor and power leads to the transmitter. Avoid 
contact with leads and terminals.
Figure 2-8. Typical Rail Mount
Transmitter Mounting Configuration
Using Threaded Style Sensor
and Assembly
Rail Mount
Transmitter
Threaded
Style Sensor
Threaded
Thermowell
Standard
Extension
Threaded Sensor
Connection Head
64
4-
000
0A
04
B