Tektronix 070-9197-00 User Manual

Page of 72
Syntax and Commands
PS2520G and PS2521G Programmer Manual
23
MEASure[:SCALar]:VOLTage[:DC]? (Query Only)
Returns actual output voltage or sense input voltage.
MEASure[:SCALar]:VOLTage[:DC]?
<NR3>
MEASure:VOLTage? might return 0.367E+1 to indicate the voltage at
the output is 3.67 V.
*OPC
The command form (*OPC) sets the operation complete bit (bit 0) in
the Standard Event Status Register (SESR) when all pending
operations finish.
The query form (*OPC?) tells the programmable power supply to
place an ASCII 1 in the Output Queue when the power supply
completes all pending operations.
*OPC
*OPC?
1
OUTPut:PROTection:CLEar (No Query Form)
Resets (clears) the Overvoltage Protection. This command duplicates
the function of the OVP RESET button.
OUTPut:PROTection:CLEar
Syntax
Returns
Examples
Syntax
Returns
Syntax