Tektronix 070-9197-00 User Manual
Syntax and Commands
PS2520G and PS2521G Programmer Manual
23
MEASure[:SCALar]:VOLTage[:DC]? (Query Only)
Returns actual output voltage or sense input voltage.
MEASure[:SCALar]:VOLTage[:DC]?
<NR3>
MEASure:VOLTage? might return 0.367E+1 to indicate the voltage at
the output is 3.67 V.
the output is 3.67 V.
*OPC
The command form (*OPC) sets the operation complete bit (bit 0) in
the Standard Event Status Register (SESR) when all pending
operations finish.
the Standard Event Status Register (SESR) when all pending
operations finish.
The query form (*OPC?) tells the programmable power supply to
place an ASCII 1 in the Output Queue when the power supply
completes all pending operations.
place an ASCII 1 in the Output Queue when the power supply
completes all pending operations.
*OPC
*OPC?
1
OUTPut:PROTection:CLEar (No Query Form)
Resets (clears) the Overvoltage Protection. This command duplicates
the function of the OVP RESET button.
the function of the OVP RESET button.
OUTPut:PROTection:CLEar
Syntax
Returns
Examples
Syntax
Returns
Syntax