Tektronix 070-9197-00 User Manual

Page of 72
Syntax and Commands
PS2520G and PS2521G Programmer Manual
25
Table 5: State of Control Settings after *RST (Cont.)
Front Panel
Control
State
Related Command
OCP 
ON/OFF
[SOURce:]CURRent:PROTection
:STATe
ON
DELAY
0
AUTO SEQ
SYSTem:AUTO
OFF
RECALL
(memory 
location)
00
OVP SET
[SOURce:]VOLTage:PROTection
[:LEVel]
MAXimum
(
PS2520G = 38.5 V
 PS2521G = 22.5 V)
SERIES/INDEP
PARA/INDEP
INSTrument:COUPle:TRACking
NONE
*RST
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]
Sets the current limit. The query form returns the current limit
setting.
[SOURce:]CURRent[:LEVel][:IMMediate]
[:AMPLitude] <NRf>|MAXimum|MINimum
[SOURce:]CURRent[:LEVel][:IMMediate]
[:AMPLitude]?
On the PS2520G
, <NRf> ranges from 0 to 1.500 (amps) for Output 1
and Output 2 and 0 to 3.000 (amps) for Output 3.
Syntax
Syntax
Parameters