Xantrex Technology 10 User Manual

Page of 68
Introduction
1–4
975-0251-01-01
Electronic Protection 
Fast-acting electronic circuits protect the inverter from extreme overloads, low 
and high battery voltage and over-temperature. They can be reset by cycling the 
power switch off and on. The fault condition must be eliminated before reset will 
occur. For example, remove the overload, recharge the batteries, or allow the unit 
to cool. See “Troubleshooting” on page 4–1.
Inverter ldle Circuit
The inverter idle circuit is an automatic energy saving feature that reduces battery 
power consumption when no load is present. Response from idle is instant. In 
most cases, the operation of the idle circuit is not noticeable. Using the remote 
control panel allows the idle circuit sensitivity to be adjusted.
Power Sharing
The Freedom 10 can automatically reduce the battery charger output, and 
therefore the AC power consumption, if appliances are turned on that threaten to 
trip the incoming circuit breaker. This feature can be adjusted using the remote 
control panel. This feature is set to protect a 15-amp source by default.