Truecharge2 Series Battery Charger Owner’s Guide
Replacing the DC Output Fuse
To replace the DC Output Fuse: 
1.
Locate the fuse cover on the charger’s top panel (see “Front Panel” on 
page 3).
2.
Loosen the screw on the fuse cover using a Phillips screwdriver.
NOTE: The screw will not separate from the cover.
3.
Pull out the blown fuse(s) gently, using the provided fuse puller.
NOTE: The fuse puller is located on the inside of the fuse cover.
4.
Install a brand new fuse(s) with same type and rating as the old one. 
See “Fuse Replacement Ratings” on page 49.
5.
Replace the fuse cover making sure that it aligns and fits perfectly, 
leaving no space for moisture or small debris to enter the 
compartment.
6.
Tighten the screw on the fuse cover but do not over-tighten.
7.
Fix the reverse polarity fault which caused the fuse to blow prior to 
reconnecting all AC and DC sources to the charger.
8.
Reconnect all AC and DC sources to the charger.
IMPROPER INSTALLATION BY AN UNQUALIFIED INSTALLER
Xantrex recommends that the installer should have knowledge and 
experience in installing electrical equipment, knowledge of the applicable 
installation codes, and awareness of the hazards involved in performing 
electrical work and how to reduce those hazards.
Failure to follow these instructions can damage the unit and/or 
damage other equipment.
ELECTRICAL SHOCK HAZARD
Disconnect all AC and DC sources to the charger and wait five minutes 
for internal voltage and energy levels to reduce to safe levels.
Failure to follow these instructions will result in death or serious 
injury.
TC2 204060 Series BattChg Owners Guide.book  Page 48  Friday, July 8, 2011  11:44 AM