24
Freedom SW 230V Installation Guide
Installing the Inverter/Charger
Step 3: Connecting the AC Input and AC Output Wires
General AC Wiring Considerations
AC and DC Wiring Separation
Do not mix AC and DC wiring 
in the same conduit or panel. Consult the applicable installation 
code for details about DC wiring and AC wiring in vicinity to each 
other.
AC Input and Output Isolation
The AC input and output 
circuits of this inverter/charger are isolated from each other when in 
invert mode to ensure safe operation. This isolation must be 
maintained in the installation, by being sure not to connect AC input 
and output wiring to a common point. For example, do not route the 
AC input and output neutrals to a common neutral bus. It is highly 
recommended to use a separate inverter load panel to distribute 
power to inverter loads. All wiring to this panel must be through the 
inverter/charger and none to the main panel upstream of the 
inverter/charger. 
IMPORTANT: Wiring the output inverter to back to the main panel 
could result in ground bonding to occur in multiple locations in 
contravention of applicable wiring codes and may result in nuisance 
tripping of Ground fault protection equipment. All wiring must be 
performed by a qualified electrician.
AC Wiring Compartment
For your reference, the AC wiring 
compartment is shown in Figure 6 on page 25.
AC Knockouts
There are two dual 1.0" (Ø34.6mm) and 3/4" 
(Ø28.3mm) trade-size knockouts on the side panel for AC wiring. 
Use the same trade size of strain relief as the trade size of the 
knockout(s) you are using.
AC Wiring Terminals
The AC wiring terminals accept cables of 
a specific size. See “AC Wiring” on page 11 for required sizes.
FIRE, ELECTRICAL SHOCK, AND ENERGY HAZARDS
Make sure wiring being connected to the inverter/charger is de-energized 
by a breaker or switch upstream. Lockout/Tagout is a recommended 
practice by many electrical contractors. Always lockout and tag 
disconnect devices before making connections. All wiring must be done 
in accordance with local and national electrical wiring codes.
Failure to follow these instructions will result in death or serious 
injury.