Mitsubishi Electronics MDS-R User Manual
7. Wiring and Connection
7 - 4
7-2 Main circuit and control circuit connectors
Do not apply a voltage other than that specified on each terminal. Failure to
observe this item could lead to rupture or damage, etc.
observe this item could lead to rupture or damage, etc.
CAUTION
7-2-1 Connector pin assignment
Unit
Terminal
MDS-R-V1-
MDS-R-V2-
Connector position
(a)
(d)
(b)
(c)
(a)
(b)
(d)
(a) CN30
(DDK)
Housing : DK-5200M-06R
Contact : DK-5RECSLP1-100 for AWG14,16
Contact : DK-5RECMLP1-100 for AWG10,12
(b)
(c)
CN31L
CN31M
(DDK)
Housing : DK-5200M-04R
Contact : DK-5RECSLP1-100 for AWG14,16
Contact : DK-5RECMLP1-100 for AWG10,12
Terminal
specification/
Pin
assignment
(d) CN22
(DDK)
Housing : DK-3200S-02R
Contact : DK-3REC2LLP1-100 for AWG14
Contact : DK-3REC2LLP1-100 for AWG14
L1 L2 L3
B
A
A
P C PE
U W
B
A
A
V PE
1
VDD
SG
2