Справочник Пользователя для Mitsubishi Electronics MDS-R

Скачать
Страница из 362
 
7. Wiring and Connection 
 
 
 
 
 
7 - 4
7-2  Main circuit and control circuit connectors 
 
 
 
Do not apply a voltage other than that specified on each terminal. Failure to 
observe this item could lead to rupture or damage, etc. 
CAUTION 
 
7-2-1  Connector pin assignment 
 
Unit 
Terminal 
 
MDS-R-V1-
 
 
MDS-R-V2-
 
Connector position 
(a) 
(d) 
(b)
 
 
(c)
(a)
(b)
(d)
 
(a) CN30
 
 
(DDK) 
Housing : DK-5200M-06R  
Contact  : DK-5RECSLP1-100 for AWG14,16 
Contact  : DK-5RECMLP1-100 for AWG10,12 
 
 
(b) 
(c) 
CN31L 
CN31M 
 
 
(DDK) 
Housing : DK-5200M-04R  
Contact  : DK-5RECSLP1-100 for AWG14,16  
Contact  : DK-5RECMLP1-100 for AWG10,12 
 
 
 
 
 
 
 
Terminal 
specification/
Pin 
assignment 
(d) CN22
 
 
(DDK) 
Housing : DK-3200S-02R   
Contact  : DK-3REC2LLP1-100 for AWG14  
 
 
L1  L2  L3 

 
A
 
 P    C  PE 
U    W 

 
A
 
V   PE
1
VDD 
 
SG 
2