-13-
4.  remove  the  screws  that  secure  the  brass 
contactor  mounting  plate  to  the  back  of  the 
electrical  box,  then  pull  the  contactors  out 
to  access  the  gray  tab  shown  in 
figure  7
pull outward on the gray tab to release each 
contactor from the mounting plate.
5.  install  the  two  110v  contactors  from  the 
Model  g0705  110v  Conversion  Kit  in  place 
of the contactors you removed in 
step 4.
6.  replace the wires you removed in step 3 to 
the corresponding terminals on the 110v con-
tactors. the wiring is the same for 110v and 
220v. refer to 
section 8: Wiring starting 
on 
page 45 for detailed wiring diagrams.
7.  locate the indicator lamp shown in figures 4 
5. disconnect the two wires from its termi-
nals, then remove the lamp.
8.  install  the  110v  indicator  lamp  from  the 
Model  g0705  110v  Conversion  Kit  in  place 
of the lamp you removed in 
step 7.
9.  Connect the wires you removed in step 7 to 
the corresponding terminals on the 110v indi-
cator lamp. the wiring is the same for 110v 
and 220v.
figure 7.
 Contactor release tab location.
gray tab
Hot
Hot
Ground
6-20 Plug
220
VAC
Ground
Neutral
Hot
Ground
L5-30 Plug
(As Recommended)
PE
V2
V1
U2
U1
U2
V1
V2
Z1
W1
Z2
W2
U1
U2
V1
V2
Z1
W1
Z2
W2
U1
To Electrical Box
Start
Capacitor
150 MFD
250 VAC
Run
Capacitor
20 MFD
450 VAC
110V Terminal 
Block Jumper
Position. 
(Wire positions
are the same for 
110V/220V)
To Electrical Box
Cord Rewired for 110V
Motor 220V
figure 8.
 Jumper positions on terminal block.
terminal Block
220v Jumper 
location
10.  locate the terminal block located in the motor 
junction box, shown in 
figure 8.
Mounting plate
Jumpers Moved 
for 110v