Grizzly G0705 User Manual

Page of 60
-14-
Model g0705 (Mfg. since 09/09)
Hot
Hot
Ground
6-20 Plug
220
VAC
Ground
Neutral
Hot
Ground
L5-30 Plug
(As Recommended)
PE
V2
V1
U2
U1
U2
V1
V2
Z1
W1
Z2
W2
U1
U2
V1
V2
Z1
W1
Z2
W2
U1
To Electrical Box
Start
Capacitor
150 MFD
250 VAC
Run
Capacitor
20 MFD
450 VAC
110V Terminal 
Block Jumper
Position. 
(Wire positions
are the same for 
110V/220V)
To Electrical Box
Cord Rewired for 110V
Motor 220V
figure 10.
 Cord rewired for 110V.
11.  use  a  phillips  screwdriver  to  remove  the 
screws  that  secure  the  two  metal  jumpers 
to the terminal block, as shown in 
figure 9
then remove both jumpers. Be careful not to 
mix up the locations of any of the wires while 
you do so.
figure 9.
 Changing motor jumper positions.
14.  install  a  neMa  5-20  plug  such  as  the  one 
shown  in 
figure  3  onto  the  power  cord,  as 
illustrated  in 
figure  10.  refer  to  section 
8:  Wiring  starting  on  page  45  for  detailed 
wiring diagrams.
12.  place both of the jumpers into the 110v loca-
tion shown in 
figure 8.
13.  replace  the  screws  you  removed  in  step 
11, making sure all wires are secured in the 
same  positions  they  were  originally  in,  as 
shown  in 
figure  8.  refer  to  section  8: 
Wiring starting on page 45 for detailed wir-
ing diagrams.