points requiring periodic lubrication are:
a.  column. a light film of oil (Mobil vactra 2 or 
iso  68  equivalent)  will  smooth  action  and 
prevent rust and corrosion.
b.  column rack. lubricate every 90 days with 
nlgi #2 grease.
c.  Quill.  a  light  coating  of  oil  (Mobil  vactra  2) 
will ensure smooth movement.
d.  Quill  rack.  lubricate  every  90  days  with 
nlgi #2 grease.
e.  table  leadscrews.  lubricate  once  each 
week with several drops of Mobil vactra 2 or 
way oil. refer to 
table leadscrews on this 
page for more information on this procedure.
f.  ball oilers. Wipe the outer surface of the ball 
fitting with a clean cloth to remove contami-
nants. press the ball of the fitting with the tip 
of the oiler. press a few drops of Mobil vactra 
2 or way oil into the ball fitting, then clean up 
any residue with a cloth.
g.  Ways.  periodically  lubricate  the  ways  with 
Mobil vactra 2 or way oil.
lubrication
figure 54.
 Ball oiler locations.
a
B
F
F
F
g
d
C
e
e
table leadscrews
every six months, or more frequently under heavy 
use, clean and lubricate the leadscrews.
items needed: 
Qty
Mobil vactra 2 or iso 68 equivalent ................. 1
stiff-Bristled nylon Brush for Cleaning .............. 1
Mineral spirits ................. as needed for cleaning
shop rags ...................... as needed for cleaning
to lubricate the leadscrews: 
1.  disConneCt Mill/drill FroM poWer!
2.  using  the  cross  handwheel,  move  the  table 
as far forward as possible.
3.  lift or remove the rubber way cover, then use 
mineral spirits and a brush to clean as much 
of the existing oil and debris as possible off 
of the cross travel leadscrew shown in 
figure 
55. allow the leadscrew to dry.
figure 55.
 Cross travel leadscrew location.
4.  apply oil to the exposed leadscrew threads, 
then move the table through its full range of 
cross motion several times to disperse the oil 
along the full length of the leadscrew.
F