Multiple RS/6000 SPs and Multiple GRFs 
227
Performance:
To get a rough overview of the data transfer rates that can be achieved in this 
scenario, the following test was performed:
1. We used 
ftp
 to conduct several file transfers of a 300 MB file from the 
nodes in SP2 to one chosen node in SP21, and at the same time used ftp 
to conduct several file transfers of a 300 MB file from the nodes in SP21 to 
a chosen node in SP2. We sent the files to /dev/null on the receiving node 
to eliminate any hard disk influence.
We saw up to about 44.5 MB/s with just one side sending data. With all 
nodes sending and receiving, we achieved a duplex throughput of about 
64 MB/s on the ATM port.
Although this is far from the theoretical maximum throughput an ATM 
OC-12c adapter can provide, it turns out that a 622 Mb/s link between two 
SP Switch Routers will be a viable solution.
7.3  HIPPI Backbone Connection
With a nominal speed of 100 MB/s duplex, connecting two GRFs with HIPPI 
media cards seems the fastest choice. But then, HIPPI cables are limited to a 
length of 25m (Ascend provides and guarantees 50m cables).
Below are the steps to set up the HIPPI backbone connection with two GRF 
routers.
Configuration assumptions:
  • The SP Switch Router HIPPI media card has been installed according to 
  • The SP Switch Router Adapter card has been installed according to 
  • The SP Switch Router Adapter card and SP processor node Switch 
adapters are in the same IP subnet on the respective SP. 
  • ARP should be enabled on the SP Switch network to provide the most 
flexibility in assigning IP addresses (strongly recommended!).
  • If ARP is disabled on the SP Switch network, the IP addresses assigned to 
the nodes must be determined by the switch node numbers.
Note: 
The SP Switch Router Adapter card will not properly forward IP data to 
nodes assigned with an IP address that is in another subnet.