Panasonic 324566-A User Manual

Page of 172
Nortel Secure Router 8012 
Hardware Description 
2 Power supply 
 
Issue 5.3 (6 April 2009) 
Nortel Networks Inc. 
2-3 
 
Figure 2-4 Front panel of the DC power module   
-48~-60V
-48~-60V
 
 
Table 2-1 Relationship of the terminal block connection of the power input cable
 
Identifier of the 
terminal block 
Input cable name 
Input cable color 
Input cable 
interface 
RTN (+) 
Power grounding 
cable 
Black 
NEG (-) 
Power cable 
Blue 
Core end terminal 
PGND 
Protection 
grounding cable 
Yellow and green 
Need not be 
connected. 
NOTE 
z
 
RTN: Return 
z
 
NEG: Negative 
z
 
PGND: Protection Ground 
 
As shown in Table 2-2 and Table 2-3, you can view the running state of the power module on 
the indicators of the Routing Process Unit (RPU) front panel. 
Table 2-2 Description of the indicators on the AC power supply module 
 
Name 
Color 
Description 
AC OK 
Green 
The power module input LED (only for the AC power 
module). 
Constant ON means the voltage input is normal (100 V 
to 240 V), and OFF means the voltage input is not 
normal.
 
RUN 
Green 
The power module indicators. 
Constant ON means the power module runs normally, 
and OFF means the power module has faults.
 
ALM 
Red 
The power module fault indicator. 
Constant ON means the power module has faults or is 
not in position.